Federal Pacific Electric stopped manufacturing under its own name in the early 1980s, but Stab-Lok load centers remain in service throughout the western United States. ESP stocks tested Federal Pacific replacement breakers in the NA, NB, NC, NE, NEF and NJL series, 15 through 400 amperes, one through three pole.

What ESP stocks

  • NA, NB and NC series — Stab-Lok residential plug-in, 15 to 100 amperes, one and two pole, including NAGF and NBGF ground-fault units
  • NE and NEF series — Stab-Lok bolt-in, 15 to 100 amperes, one through three pole
  • NJL, NKL and NJJ frames — 150 to 400 amperes, two and three pole, 600 volt
  • XM and XJL — later American and Challenger-era units, 225 to 600 amperes

Every breaker is inspected, cleaned and tested to ESP Product Standards before it ships, and carries a one-year operational guarantee. Reconditioned units are tested for continuity, insulation resistance and mechanical operation; surplus new units are verified against their catalog number and inspected for shelf damage.

Common questions

What is the concern about Stab-Lok breakers?

Federal Pacific Stab-Lok panels have been the subject of long-running debate over trip reliability. The Consumer Product Safety Commission investigated in the early 1980s and closed the matter without issuing a recall; independent testing published since has reported elevated failure-to-trip rates, and many home inspectors and insurers flag these panels during assessments. Whether a particular panel should be replaced outright rather than fitted with replacement breakers is a judgement for a licensed electrician who can inspect the installation. ESP supplies these breakers for like-for-like replacement in panels that remain in service.

How is a Federal Pacific breaker identified?

The catalog number is printed on the breaker face, usually beginning with N for Stab-Lok units — NA, NB, NC, NE and NEF are the common residential and light commercial series. Larger NJL, NKL and NJJ frames carry the number on the trip unit label. Panels manufactured after the line changed hands may be labelled Challenger or American rather than Federal Pacific.

Are Challenger and Federal Pacific breakers interchangeable?

Challenger and American acquired the Stab-Lok line, and many units of the same catalog number share dimensions and stab configuration across the three labels. Interchangeability depends on the specific catalog number and the panel it is going into, and should be confirmed against the panel schedule or by a licensed electrician rather than assumed from the label alone.